Overview
The Ammonia Gas Sensor Device, in combination with the principle of coulometry, delivers a high-precision gas detection technology. The higher the ammonia concentration the faster the sensor will be drained. Therefore the sensor lifetime will deteriorate rapidly and more maintenance will be needed.
Features
Smart measuring system
Works on back Ammonia concentration continually
Combined with intelligent algorithms it has better adaptability to the environment
Higher accuracy in detection and stable zero point
With pump, no calibration with NH3 gas needed
New microcircuit design, strong anti-electromagnetic interference ability
No temperature and humidity influence
RS485 output, 5-12V DC power
Stainless steel housing, water and dust proof, anti-corrosion
The detection range is automatically adjusted to the concentration range of the
measured gas, from ppb to higher ppm level
Continuously monitors its own fault conditions, Sensor, Pump, Power etc.
RoHS eco-friendly design
Self-monitoring of the sensor function
Technology Specifications
Principle
Repeatability
Settling Time
Response Time
Solid Polymer Electrochemical Sensing Technology
≤ 2%
Note: Exposure to harsh chemicals, high concentrations of alcohol, acetone, and ethanol gas during storage may lead to extended warm-up time
Dependent on the selected measuring period, between 1 to 10min
Calibration Gas
The gas distribution standard uses clean air as the background gas, the humidity is 50%, and the normal temperature environment
Sensor Life Expectancy
≥ 2 years
Long-Term Drift
< 1% /month
Output
RS485 (Modbus protocol), Baud rate: 9600
Get Data Command
Working Voltage
Maximum Current Consumption
Maximum Power Consumption
Working Temperature
See ECtox protocol document for details
5 - 12V DC
1 A
5 W
-20°C to +55°C
Product
Ammonia Gas Sensor Device
Partnumber
05-ECtox-NH3-500-01
05-ECtox-HT-NH3-500-01
Range
0-500ppm
0-500ppm
Resolution
0.1ppm
0.1ppm
Accuracy
± 5% F.S
± 5% F.S
Applications
· Livestock Farming
· High Concentration Monitoring
· Leakage Detection
· High Temperature Conditions
The ammonia concentration in the livestock industry has various negative effects on the animals and our environment. In a high ammonia concentrated environment the livestock has a higher risk of contracting a disease. The air surrounding the farm, both inside and outside, is polluted and has a pungent smell.
ECtox’s big advantage, while continuously working with a high ammonia concentration, is its long lifetime. A pump easily transports the gas to the sensor without the need to calibrate. The sensor can be used for livestock farms, ammonia leakage detection and cooling storages. The output signal, RS485 (Modbus), will effortlessly connect with a gas detector, DCS, PLC or wireless systems.
Note: Temperature (0-25) ℃, humidity (30-50)% RH, the measured gas concentration is within the range, there is no gas environment that affects the warm-up time mentioned above
Working Humidity
15-95% RH. Non-condensing
Atm ± 10% Keep Stable Pressure
159 x 43 mm
Working Pressure
Size
Weight
ECtox: 450g
Temperature and humidity sensor data
Temperature Range: -40℃ to +85℃ Relative error: ± 0.2 ℃
Humidity Range: 10 - 95% RH. non-condensing Relative error: ± 2%
Warranty
12 months
Ammonia Gas Sensor Device
Cable
02-LEMO-HXT-1423-1M-01
02-LEMO-HXT-1423-10M-01
1 m
10 m
Cable
Fixed Assembly
02-ECtox-Bracket-SS-01
Optional accessories
Note: 05-ECtox-HT in above order information are for higher temperature application.
· Process Ammonia monitoring
· Cooling Storage
AQ Sense
Copyright © 2024 AQ Sense GmbH